Crankcase Oil Mist Detector
criticalParent: Lubrication System
Components for this Group (2)
Schaller Visatron VN215+ OMD
MAN Energy Solutions ME/ME-C
· Supplier: Schaller Automation
Common Failures:
- • Sensor fouling giving false alarms
- • Sample pipe blockage
- • Reference cell degradation
- • Relay output failure
Service: SOLAS mandatory. Test weekly. Clean sensor optics every 4,000 hrs. Replace reference cell every 2 years.
Weight: 8.0 kg
GEA Westfalia OMD / Schaller VN215+
WIN-GD X-DF
· Supplier: GEA / Schaller Automation
Common Failures:
- • Sensor window fouling
- • Sample extraction fan failure
- • False alarm from crankcase ventilation change in gas mode
Service: Same as diesel — SOLAS mandatory regardless of fuel. Test weekly.
Weight: 8.0 kg