Sensors & Transmitters
mediumParent: Electronic Control System
Components for this Group (1)
WIN-GD Sensor Suite (pressure, temp, speed, knock)
WIN-GD X-DF
· Supplier: WIN-GD / Danfoss / ABB
Common Failures:
- • Knock sensor calibration drift (critical for gas mode)
- • Exhaust gas temp sensor failure
- • Scavenge pressure transmitter error
- • Speed pickup contamination
Service: Knock detection sensors critical for X-DF gas mode — prevents detonation. Calibrate every 4,000 hrs.
Weight: 2.0 kg