OS
← Heat Exchangers

Charge Air Cooler (Standalone)

high
Standalone charge air cooler units (separate from engine-integrated SAC)
8000h
Service Interval
20 yr
Typical Lifetime

Typical Manufacturers

Alfa Laval Vestas MAN PrimeServ

Known Models (3)

Alfa Laval ACE Charge Air
Alfa Laval ACE Charge Air
1500 kW · Charge Air / Freshwater
Common Failures:
  • • Fin fouling with oil mist
  • • Water-side scaling
  • • Air-side condensation corrosion
Service: Clean air-side with approved degreaser; check for water leaks into charge air.
Spares: Alfa Laval: Dichtungssatz an Bord vorhalten. Platten-Reinigungschemikalien bevorraten. Lead time: 2-6 Wochen.
MAN PrimeServ SAC-TC 200
MAN PrimeServ SAC-TC 200
2000 kW · Charge Air / Freshwater
Common Failures:
  • • Water leak into air side
  • • Corrosion from acidic condensate
  • • Gasket failure
Service: OEM replacement for MAN engines; use MAN-specified gaskets and seals.
Spares: MAN PrimeServ: Dichtungssatz an Bord vorhalten. Platten-Reinigungschemikalien bevorraten. Lead time: 2-6 Wochen.
Vestas aircoil CAC-150
Vestas aircoil CAC-150
1200 kW · Charge Air / Freshwater
Common Failures:
  • • Tube leakage
  • • Fin corrosion
  • • Reduced cooling from fouling
Service: Vestas aircoil; pressure test at class survey; clean air fins.
Spares: Vestas: Dichtungssatz an Bord vorhalten. Platten-Reinigungschemikalien bevorraten. Lead time: 2-6 Wochen.