← Emergency Power

Emergency Generator Set

medium
Emergency diesel generator sets for SOLAS-compliant emergency power supply

Known Models (20)

Caterpillar C4.4 Marine Emergency GenSet
Caterpillar C4.4 Marine Emergency GenSet
40-100 kVA · 75.0 kW · Emergency Equipment · Emergency GenSet
power_kw: 75
type: Emergency GenSet
Common Failures:
  • • Starting motor failure
  • • Fuel lift pump failure
  • • Coolant level sensor fault
  • • ECM communication error
Service: Cat electronic engine. Weekly auto-start test. Annual load test. Cat dealer service network worldwide.
Spares: Caterpillar: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Caterpillar C7.1 Marine Emergency GenSet
Caterpillar C7.1 Marine Emergency GenSet
100-250 kVA · 200.0 kW · Emergency Equipment · Emergency GenSet
power_kw: 200
type: Emergency GenSet
Common Failures:
  • • Injector solenoid failure
  • • Turbo bearing failure
  • • Aftercooler leak
  • • Battery charger fault
Service: Electronic fuel injection. Weekly test with load transfer. Annual full load bank test per SOLAS.
Spares: Caterpillar: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Caterpillar C9.3 Marine Emergency GenSet
Caterpillar C9.3 Marine Emergency GenSet
200-400 kVA · 340.0 kW · Emergency Equipment · Emergency GenSet
power_kw: 340
type: Emergency GenSet
Common Failures:
  • • HEUI injector failure
  • • Turbocharger oil seal leak
  • • Alternator diode failure
  • • Coolant pump leak
Service: HEUI fuel system — monitor injection oil pressure. Weekly test. Major service at 2000 hrs intervals.
Spares: Caterpillar: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Corvus Energy AS Dolphin NxtGen Power
Corvus Energy AS Dolphin NxtGen Power
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE00004Z6
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Corvus Energy AS: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Corvus Energy AS Moray
Corvus Energy AS Moray
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE00004VJ
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Corvus Energy AS: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Corvus Energy AS Dolphin NxtGen
Corvus Energy AS Dolphin NxtGen
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE00004UB
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Corvus Energy AS: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Corvus Energy AS Dolphin Energy and Power v.1.3
Corvus Energy AS Dolphin Energy and Power v.1.3
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE0000484
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Corvus Energy AS: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Corvus Energy AS ORCA Energy
Corvus Energy AS ORCA Energy
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE000026N
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Corvus Energy AS: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Corvus Energy Fuel Cell AS Pelican Fuel Cell System
Corvus Energy Fuel Cell AS Pelican Fuel Cell System
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE00004XZ
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Corvus Energy Fuel Cell AS: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Corvus Energy Inc. Blue Whale
Corvus Energy Inc. Blue Whale
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE00004VC
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Corvus Energy Inc.: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Corvus Energy Inc. Blue Marlin
Corvus Energy Inc. Blue Marlin
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE00004G7
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Corvus Energy Inc.: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Cummins 6BT Marine Emergency GenSet
Cummins 6BT Marine Emergency GenSet
75-150 kVA · 120.0 kW · Emergency Equipment · Emergency GenSet
power_kw: 120
type: Emergency GenSet
Common Failures:
  • • Mechanical fuel pump wear
  • • Turbo wastegate stuck
  • • Alternator brush wear
  • • Starter solenoid failure
Service: Legendary reliability. Mechanical fuel injection — no electronics to fail. Weekly test. Simple maintenance.
Spares: Cummins: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Cummins 6CT Marine Emergency GenSet
Cummins 6CT Marine Emergency GenSet
150-300 kVA · 240.0 kW · Emergency Equipment · Emergency GenSet
power_kw: 240
type: Emergency GenSet
Common Failures:
  • • Injector nozzle wear
  • • Turbo bearing failure
  • • Aftercooler corrosion
  • • Governor instability
Service: Robust Cummins design. Available worldwide. Weekly test under load. Major service every 1500-2000 hrs.
Spares: Cummins: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Glamox Marine and Offshore GmbH Series 1445xxx...
Glamox Marine and Offshore GmbH Series 1445xxx...
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE00002A3
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Glamox Marine and Offshore GmbH: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Glamox Marine and Offshore GmbH Lighting Fixture for Replenishment at Sea HIRAS green, HIRAS white and HIRAS red
Glamox Marine and Offshore GmbH Lighting Fixture for Replenishment at Sea HIRAS green, HIRAS white and HIRAS red
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE00001VV
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Glamox Marine and Offshore GmbH: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Glamox Marine and Offshore GmbH LRRLS room light, LRCLS ceiling light
Glamox Marine and Offshore GmbH LRRLS room light, LRCLS ceiling light
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE00004BF
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Glamox Marine and Offshore GmbH: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
MAN D2676 Emergency GenSet
MAN D2676 Emergency GenSet
200-500 kVA · 397.0 kW · Emergency Equipment · Emergency GenSet
power_kw: 397
type: Emergency GenSet
Common Failures:
  • • Common rail pressure sensor fault
  • • DPF blockage (if fitted)
  • • Starter motor failure
  • • Coolant thermostat stuck
Service: MAN truck-derived marine engine. Good European service network. Weekly test under load. Service every 500 hrs.
Spares: MAN: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
MTU Series 2000 Emergency GenSet
MTU Series 2000 Emergency GenSet
500-2000 kVA · 1600.0 kW · Emergency Equipment · Emergency GenSet
power_kw: 1600
type: Emergency GenSet
Common Failures:
  • • Common rail injector failure
  • • EGR system malfunction
  • • Coolant pump seal leak
  • • ECU software fault
Service: High-end MTU — Rolls-Royce Power Systems. MTU ValueCare service contract recommended. Electronic engine — specialist service.
Spares: MTU: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
MTU Series 4000 Emergency GenSet
MTU Series 4000 Emergency GenSet
1000-4000 kVA · 3200.0 kW · Emergency Equipment · Emergency GenSet
power_kw: 3200
type: Emergency GenSet
Common Failures:
  • • Turbocharger failure
  • • Fuel injection system fault
  • • Charge air cooler leak
  • • Power turbine blade damage
Service: Premium segment. MTU service engineer required for major work. Comprehensive monitoring system included.
Spares: MTU: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.
Zhenjiang Marine Electrical Appliance Co.,Ltd CSD
Zhenjiang Marine Electrical Appliance Co.,Ltd CSD
Per SOLAS emergency power requirements · Emergency Equipment
source: dnv-approval-finder
model_number: TAE00003SW
Common Failures:
  • • Batterie-Kapazitätsverlust durch Alterung
  • • Generator-Startversagen bei Kaltstart
  • • Kraftstoff-Alterung bei seltener Nutzung
  • • Automatik-Start-Schaltung Relais-Ausfall
Service: Generator-Test wöchentlich. Batterie-Kapazitätstest quartalsweise. Automatik-Start Test monatlich. Kraftstoff-Qualität jährlich prüfen.
Spares: Zhenjiang Marine Electrical Appliance Co.,Ltd: Batterie-Sätze und Starter-Komponenten an Bord. Lead time: 2-4 Wochen.