Marine Chiller
medium
Chilled water plant for accommodation and machinery space air conditioning
Known Models (7)
Carrier 30XA
200-500 kW cooling
· 150.0 kW
· Refrigerant R-134a
· Screw Chiller Air-Cooled
medium: Refrigerant R-134a
power_kw: 150
type: Screw Chiller Air-Cooled
Common Failures:
- • Screw compressor bearing wear
- • Condenser fan motor failure
- • Expansion valve sticking
- • Refrigerant leak at joints
Service: Air-cooled — suitable for vessels with limited seawater access. Annual refrigerant charge check. Compressor oil analysis every 4000 hrs.
Spares: Ersatzteile über Carrier oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Carrier 30HXC
500-2000 kW cooling
· 400.0 kW
· Refrigerant R-134a
· Centrifugal Chiller Water-Cooled
medium: Refrigerant R-134a
power_kw: 400
type: Centrifugal Chiller Water-Cooled
Common Failures:
- • Impeller blade erosion
- • Motor winding insulation breakdown
- • Oil pump failure
- • Condenser tube fouling
Service: Centrifugal — for large cruise ships and naval vessels. Condenser tube cleaning every 6 months (seawater cooled).
Spares: Ersatzteile über Carrier oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Daikin EWAD-C
100-800 kW cooling
· 250.0 kW
· Refrigerant R-410A/R-134a
· Chiller Marine
medium: Refrigerant R-410A/R-134a
power_kw: 250
type: Chiller Marine
Common Failures:
- • Scroll compressor failure
- • Plate heat exchanger fouling
- • Refrigerant charge loss
- • Control board fault
Service: Daikin quality. Plate-type evaporator/condenser for compact installation. Annual leak check required (F-Gas regulation).
Spares: Ersatzteile über Daikin oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Heinen & Hopman HVAC System (Complete)
50-5000 kW cooling (system)
· Chilled Water / Conditioned Air
· Complete Marine HVAC System
type: Complete Marine HVAC System
Common Failures:
- • Chiller unit failure
- • AHU coil corrosion
- • Duct insulation degradation
- • Control system BMS fault
Service: Turnkey marine HVAC. Heinen & Hopman global service network. Annual system performance review recommended.
Spares: Ersatzteile über Heinen & Hopman oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Johnson Controls (York) YCWM
300-1500 kW cooling
· 350.0 kW
· Refrigerant R-134a
· Screw Chiller Water-Cooled
medium: Refrigerant R-134a
power_kw: 350
type: Screw Chiller Water-Cooled
Common Failures:
- • Compressor unloader valve failure
- • Condenser tube biofouling
- • Oil separator element saturation
- • Expansion valve hunting
Service: York YCWM widely used on cruise ships. Johnson Controls service network. Annual eddy current test on condenser tubes.
Spares: Ersatzteile über Johnson Controls (York) oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Novenco Marine & Offshore HVAC System (Complete)
50-3000 kW cooling (system)
· Chilled Water / Conditioned Air
· Complete Marine HVAC System
type: Complete Marine HVAC System
Common Failures:
- • Chiller refrigerant leak
- • AHU damper actuator failure
- • FCU motor burnout
- • BMS communication loss
Service: Novenco HVAC for naval and offshore. Specialized in harsh environments. Annual commissioning report.
Spares: Ersatzteile über Novenco Marine & Offshore oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Trane CGAM
100-500 kW cooling
· 140.0 kW
· Refrigerant R-134a
· Screw Chiller Air-Cooled Marine
medium: Refrigerant R-134a
power_kw: 140
type: Screw Chiller Air-Cooled Marine
Common Failures:
- • Screw compressor discharge valve leak
- • Condenser coil corrosion from salt air
- • Expansion valve malfunction
Service: Trane marine chiller. Coil coating essential for marine environment. Annual refrigerant charge verification.