← Oily Water Separator

15 ppm OWS

medium
Oily water separators meeting IMO MEPC.107(49) for 15 ppm oil discharge

Known Models (5)

Alfa Laval EPC 50 OWS
Alfa Laval EPC 50 OWS
5 m³/h · Bilge Water · Membrane OWS
medium: Bilge Water
type: Membrane OWS
Common Failures:
  • • OCM sensor fouling giving false high readings
  • • Membrane fouling
  • • Auto-recirculation valve failure
  • • Three-way valve stuck
Service: MARPOL Annex I. PSC hot topic — maintain oil record book. Clean OCM sensor weekly. Membrane replacement every 12-18 months.
Spares: Alfa Laval: O-Ring-Satz und Betriebswasserventil an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
Compass Water Solutions Marine OWS
Compass Water Solutions Marine OWS
1-5 m³/h · Bilge Water · Electrocoagulation OWS
medium: Bilge Water
type: Electrocoagulation OWS
Common Failures:
  • • Electrode wear
  • • Power supply failure
  • • Sludge removal system fault
  • • pH control issue
Service: Electrocoagulation — no consumable filter elements. Electrode replacement per operating hours. Good for emulsified oil.
Spares: Compass Water Solutions: O-Ring-Satz und Betriebswasserventil an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
Facet/Parker ClearSea Marine OWS
Facet/Parker ClearSea Marine OWS
1-10 m³/h · Bilge Water · Multi-Stage Coalescer OWS
medium: Bilge Water
type: Multi-Stage Coalescer OWS
Common Failures:
  • • Filter element blockage
  • • Differential pressure alarm
  • • OCM sensor contamination
  • • Solenoid valve stuck
Service: Multi-stage filtration for reliable 15 ppm. Replace filter elements per differential pressure. Annual OCM calibration.
Spares: Facet/Parker: O-Ring-Satz und Betriebswasserventil an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
RWO (Veolia) SKIT/S Marine OWS
RWO (Veolia) SKIT/S Marine OWS
0.5-5 m³/h · Bilge Water · Coalescer + Carbon OWS
medium: Bilge Water
type: Coalescer + Carbon OWS
Common Failures:
  • • Coalescer element saturated
  • • Activated carbon exhaustion
  • • OCM calibration drift
  • • Solenoid valve failure
Service: RWO (now Veolia/Damen) — most common OWS type. Replace coalescer/carbon elements per maintenance schedule. PSC inspection focus.
Spares: RWO (Veolia): O-Ring-Satz und Betriebswasserventil an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.
Victor Marine VMS Marine OWS
Victor Marine VMS Marine OWS
0.5-2.5 m³/h · Bilge Water · Coalescer OWS
medium: Bilge Water
type: Coalescer OWS
Common Failures:
  • • Coalescer element clogging
  • • OCM failure
  • • Pump seal leakage
  • • Control panel fault
Service: Simple and reliable design. Replace coalescer elements every 12 months. Calibrate OCM monthly.
Spares: Victor Marine: O-Ring-Satz und Betriebswasserventil an Bord vorhalten. Lead time: 2-6 Wochen je nach Hersteller.