Known Models (3)

ABB Marine Dry Transformer
ABB Marine Dry Transformer
50-2000 kVA · Electrical Power Transformation · Dry-Type Distribution Transformer
type: Dry-Type Distribution Transformer
Common Failures:
  • • Winding insulation breakdown
  • • Cooling fan failure
  • • Terminal connection loosening
  • • Overtemperature from ventilation blockage
Service: Cast-resin = no oil, no fire risk. Clean resin surfaces with dry air annually. Check terminal torques. Monitor winding temperature.
Spares: Ersatzteile über ABB oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Siemens GEAFOL Marine Transformer
Siemens GEAFOL Marine Transformer
100-3000 kVA · Electrical Power Transformation · Dry-Type Cast-Resin Transformer
type: Dry-Type Cast-Resin Transformer
Common Failures:
  • • Resin cracking from thermal cycling
  • • Fan motor failure
  • • Temperature sensor fault
  • • Tap connection overheating
Service: GEAFOL marine-certified. Annual insulation test. Clean with dry compressed air. Thermographic survey during load.
Spares: Ersatzteile über Siemens oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Trafo Power Solutions Marine Distribution Transformer
Trafo Power Solutions Marine Distribution Transformer
100-5000 kVA · Electrical Power Transformation · Oil-Immersed Distribution Transformer
type: Oil-Immersed Distribution Transformer
Common Failures:
  • • Oil leakage from gasket aging
  • • Winding insulation degradation
  • • Buchholz relay trip
  • • Tap changer contact wear
Service: Oil-filled — fire risk in ER. Annual oil analysis (DGA). Buchholz relay test annually. Consider replacement with dry-type at next drydock.
Spares: Ersatzteile über Trafo Power Solutions oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.