SOLAS A Life Raft
medium
SOLAS A pack inflatable life rafts for unlimited voyages
Known Models (335)
DSB Engineering DSB SOLAS A 25P
25 persons
· Crew Evacuation
persons: 25
solas_pack: A
Common Failures:
- • Inflation system failure
- • Canopy deterioration
- • Equipment pack water damage
Service: Budget alternative, service at approved stations
Spares: DSB Engineering: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
DSB Engineering DSB SOLAS A 12P
12 persons
· Crew Evacuation
persons: 12
solas_pack: A
Common Failures:
- • Inflation failure
- • Canopy UV degradation
- • HRU failure
Service: Budget alternative
Spares: DSB Engineering: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Fujikura SOLAS A Life Raft 6P
6 persons
· Crew Evacuation
persons: 6
solas_pack: A
origin: Japan
Common Failures:
- • CO2 cylinder corrosion
- • Canopy fabric degradation
- • HRU expiry
Service: ClassNK approved. Common on Japanese-built vessels.
Spares: Fujikura: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Fujikura SOLAS A Life Raft 12P
12 persons
· Crew Evacuation
persons: 12
solas_pack: A
origin: Japan
Common Failures:
- • Inflation system malfunction
- • Painter line chafe
- • Equipment pack degradation
Service: Annual service at approved station
Spares: Fujikura: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Fujikura SOLAS A Life Raft 25P
25 persons
· Crew Evacuation
persons: 25
solas_pack: A
origin: Japan
Common Failures:
- • CO2 cylinder leak
- • Floor inflation failure
- • Canopy tear
Service: Davit-launched version available
Spares: Fujikura: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Fujikura SOLAS A Life Raft 16P
16 persons
· Crew Evacuation
persons: 16
solas_pack: A
origin: Japan
Common Failures:
- • CO2 inflation failure
- • Canopy fabric tear
- • Floor inflation failure
Service: ClassNK approved. Mid-size Fujikura raft.
Spares: Fujikura: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Fujikura SOLAS A Life Raft 20P
20 persons
· Crew Evacuation
persons: 20
solas_pack: A
origin: Japan
Common Failures:
- • Inflation system malfunction
- • Painter chafe
- • Equipment pack degradation
Service: Annual service at approved station
Spares: Fujikura: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Lalizas Oceano, DL-12/-15/-16/-20/-25 (davit-launched type)
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007AM
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Lalizas Oceano, OR-6/-10/-25/-30/-50/-65/-100
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00007AK
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 70176-Advanced Inflant lifejacket SOLAS-(LSA Code) 2010
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006HD
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Lamda Auto 150 N (code 71107, 711071, 711072, and 711073)
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000091B
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. LAMDA Auto 275 N
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000091D
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Lalizas NEPTUNE
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00004F0
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. LALIZAS OCEANO -6, -8, -10, -12, -15, -16, -20, -25, -30, -35
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003T3
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Lalizas Oceano, Throw over-board Self-Righting -6, -8,-10, -12, -15, -16, -20, -25, -30, -35, -50, -66, -100
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003B4
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 71327 - Self-Contained Breathing Apparatus 6L SOLAS/MED, 71328 - Self-Contained Breathing Apparatus 9L SOLAS/MED
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003DR
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 70321 - Emergency Evacuation Breathing Device "ESCAPE -15", SOLAS/MED
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003DS
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. "70030" POSITION-INDICATING LIGHTS FOR LIFEBUOYS
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB000052W
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 70461-LALIZAS Thermal Protective Aid "Alusafe-T" - LSA Code
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00006WX
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Lifebuoy type 2.5 kg (code 70090) and Lifebuoy type >4 kg (code 70110)
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00001J1
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 71326- Intrinsically safe Lifebuoy Light
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003TY
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 71325 Lifebuoy Light SOLAS / MED
Persons capacity per SOLAS certification
· Crew Evacuation
imo_approved: True
source: dnv-approval-finder
model_number: MEDB00003TX
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. LAMDA Auto 330 N
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
model_number: MERB0001N72
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 70178 - Advanced Adult´s Lifejacket SOLAS-(LSA Code) 2010
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
model_number: MERB00006HF
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 70177 - Advanced Child Lifejacket SOLAS-(LSA Code) 2010
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
model_number: MERB00006HE
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 70176 - Advanced Infant Lifejacket SOLAS-(LSA Code) 2010
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
model_number: MERB00006HD
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Lamda Auto 150 N
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
model_number: MERB000091B
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 71327 - Self-Contained Breathing Apparatus 6L SOLAS, 71328 - Self-Contained Breathing Apparatus 9L SOLAS
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
model_number: MERB00003DR
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 70321 - Emergency Evacuation Breathing Device "ESCAPE -15", SOLAS
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
model_number: MERB00003DS
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 71325 Lifebuoy Light SOLAS
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
model_number: MERB00003TX
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. ALKALITE II / (Code 72348)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
model_number: 75201/A0 UK
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Safelite IV / (Code 72349)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
model_number: 75202/A1 UK
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. LALIZAS Hydrostatic Release for Life Rafts
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
model_number: 77021/A0 UK
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. LIFEJACKETS (72214 - Lalizas Compact Folding Adult Lifejacket SOLAS LSA Code 2016, Orange - 72241 - Lalizas Compack Folding Adult Lifejacket SOLAS LSA Code 2016, Yellow)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
model_number: LR24129141UKMB
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Hand flares (pyrotechnics) (747881 LALIZAS Hand Flare ASTROS II, Red)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
model_number: LR2636764UKMB
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Rocket Parachute Flares (Pyrotechnics) (747871 LALIZAS Parachute Rocket ASTROS II, Red)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
model_number: LR2637231UKMB
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. Buoyant Smoke Signals (Pyrotechnics) (74789-LALIZAS Astros orange buoyant smoke signal)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
model_number: LR2637498UKMB
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Lalizas Hellas S.A. 73595-LALIZAS Hydrostatic Release for Life Rafts
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
model_number: MERD00001AM-1
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Lalizas Hellas S.A.: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Norsafe (Survitec) NS Gravity Davit GD-35
35 person lifeboat
· Crew Evacuation
· gravity
type: gravity
compliance: SOLAS_III
capacity_persons: 35
Common Failures:
- • Tricing pendant corrosion
- • Gripes mechanism wear
- • Davit arm pin seizure
Service: Replace tricing pendants every 5 years; exercise gripes monthly.
Spares: Norsafe (Survitec): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Norsafe (Survitec) NS Single-Arm Davit SAD-6
6 person rescue boat
· Crew Evacuation
· single_arm_slewing
type: single_arm_slewing
compliance: SOLAS_III
capacity_persons: 6
Common Failures:
- • Slewing bearing corrosion
- • Hoisting wire fatigue
- • Limit switch water ingress
Service: Test weekly; inspect wire before every launch.
Spares: Norsafe (Survitec): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Norsafe (Survitec) Magnum 650 Fast Rescue Boat
6 persons, 25+ knots
· Crew Evacuation
· fast_rescue
type: fast_rescue
length_m: 6.5
speed_knots: 25
capacity_persons: 6
Common Failures:
- • Engine raw water cooling blockage
- • Hull gelcoat cracking
- • Steering cable stretch
Service: Flush engine cooling system after every use; inspect gelcoat quarterly.
Spares: Norsafe (Survitec): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Pains Wessex (Survitec) Mk8A Parachute Rocket
1 signal
· Crew Evacuation
· parachute_rocket
type: parachute_rocket
color: red
solas: True
Common Failures:
- • Expired shelf life
- • Trigger mechanism corrosion
- • Damp storage
Service: Survitec product. 3-year shelf life.
Spares: Pains Wessex (Survitec): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Pains Wessex (Survitec) Mk9 Red Hand Flare
1 signal
· Crew Evacuation
· hand_flare
type: hand_flare
color: red
solas: True
Common Failures:
- • Shelf life expiry
- • Igniter mechanism failure
Service: Survitec product. Replace every 3 years.
Spares: Pains Wessex (Survitec): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Pains Wessex (Survitec) Speedline 250 LTA
250m range
· Crew Evacuation
· line_throwing
type: line_throwing
range_m: 250
solas: True
Common Failures:
- • Rocket expiry
- • Line deterioration
- • Case seal failure
Service: 250m range. 4 sets per SOLAS requirement.
Spares: Pains Wessex (Survitec): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 06 man Open Reversible Inflatable Liferaft - HSC pack - Type ORIL HSC R 06 / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 06 man throw-over self-righting SOLAS A and B pack inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 06 man throw-over self-righting SOLAS A and B pack inflatable liferaft, packed in container / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 08 man Davit Launched SOLAS A and B pack inflatable liferaft / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 08 man throw-over self-righting SOLAS A and B pack inflatable liferaft / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 100 man open reversible inflatable liferaft - HSC pack : ORIL HSCR 100V. / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 100 man Open Reversible Inflatable Liferaft - HSC pack. / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 100 man throw-overboard self-righting SOLAS A and B pack inflatable liferaft / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 10 man Open Reversible Inflatable Liferaft - HSC pack - TYPE ORIL HSC R 10 / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 10 man throw-overboard self-righting SOLAS A and B pack inflatable liferaft. / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 12 man throw-over self-righting SOLAS A and B pack inflatable liferaft / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 12 or 16 man davit-launched SOLAS A and B pack inflatable liferaft / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 150 man throw overboard automatically self-righting SOLAS A and B pack inflatable liferaft. / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 150 TO SR V / 150 Man Throw-Overboard Automatically self-righting liferafts SOLAS B pack / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 151 man open reversible inflatable liferaft - HSC pack : ORIL HSCR 151V. / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 20 man Open Reversible Inflatable Liferaft - HSC pack - TYPE ORIL HSC R 20 / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 25 man davit-launched self-righting SOLAS A and B pack inflatable liferaft. / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 25 man throw-over self-righting SOLAS A and B pack inflatable liferaft, packed in cylindrical container / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 25 man throw-over SOLAS A and B pack inflatable liferaft, packed in cylindrical container / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 30 man Open Reversible Inflatable Liferaft - HSC pack / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 37 man davit-launched automatically self-righting inflatable liferaft. / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 37 man davit-launched SOLAS A and B pack inflatable liferaft. / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 37 man throw-over self-righting SOLAS A and B pack inflatable liferaft, packed in cylindrical container / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 37 man throw-over SOLAS A and B pack inflatable liferaft, packed in container / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 50 man Open Reversible Inflatable Liferaft - HSC pack. / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 50 man throw-overboard self-righting SOLAS A and B pack inflatable liferaft / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED 50 man throw-overboard SOLAS A and B pack inflatable liferaft. / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED Canopied Reversible inflatable liferaft, B pack - Throw-overboard - capacity 50 persons - Type : 50 TO CR / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED ESS MES SIS 50TO / 50TOSR / 150 TOSRV / ORIL 100V / ORIL151V / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED FRB 600 E Frame
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED Inflatable Liferaft - 12 person, 16 person, 20 person, 25 person davit launched canopied Surviva
MkIV inflatable liferaft hull, packaged for extended service intervals. (RFD Endura R’ (also known as ‘Survitec ESR’, ‘DSB LR07E’, ‘Survitec Zodiac ESP’, ‘Crewsaver ESR’ & ‘Elliot ESR’))
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED Inflatable Liferafts - 6-person, 8-person, 10-person, 12-person, 16-person, 20-person, 25-person throw-over
/roll-over canopied Surviva MkIV inflatable liferaft hull, packaged for extended service
Intervals. (RFD Endura R’ (also known as ‘Survitec ESR’, ‘DSB LR07E’, ‘Survitec Zodiac ESP’, ‘Crewsaver ESR’ & ‘Elliot ESR’).)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED Marine Evacuation System with Small Inflatable Slide / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED Means of Rescue, 10 persons / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED MES MIS / with a Medium Inflatable Slide (4.8/6.2/7.7/9.3/10.9/12.5 m) / and liferafts (100 TOSR V/150 TOSR V/ORIL 100V/ORIL 151V) / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED MOR MES MIS / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED RIBO 450
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED RIBO 600
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
SURVITEC GROUP LIMITED SurvitecZodiac Open Reversible Liferaft HSCR 65 / Trademarks: SURVITEC, ENDURA, CREWSAVER, ELLIOT, DSB, SURVITECZODIAC, RFD, SSP, BRUDE, RFD TOYO
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: SURVITEC GROUP LIMITED: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Survitec RFD SeaMaster SOLAS A Life Raft
20 persons
· Crew Evacuation
Common Failures:
- • Painter line UV degradation
- • Inflation valve leak
- • Sea anchor tangling
Service: Annual service per MSC.1/Circ.1328. Check painter line attachment every drill.
Spares: Survitec: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Survitec 1000 Series Immersion Suit
Universal size, 6 hr thermal protection
· Crew Evacuation
Common Failures:
- • Face seal deterioration
- • Retro-reflective tape peeling
- • Buddy line clip breakage
Service: Annual inspection and air test. Store away from direct sunlight and heat sources.
Spares: Survitec: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Survitec Crewsaver SOLAS Life Jacket
275 N buoyancy, auto/manual inflate
· Crew Evacuation
· Inflatable Life Jacket
Common Failures:
- • Oral inflation tube valve leak
- • Light battery expiry
- • Retro-reflective tape peeling
Service: Annual re-arming kit check. Light and whistle function test every drill.
Spares: Survitec: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
✔ Pros
- • Meets SOLAS requirements for international maritime safety
- • Designed for easy donning and secure fit
- • Equipped with a reliable inflation system and oral inflation tube
- • Features retro-reflective tape for enhanced visibility
- • Regular service and maintenance are relatively straightforward
⚠ Cons
- • Oral inflation tube valve leaks have been reported
- • Light battery expiry can be a maintenance issue
- • Retro-reflective tape peeling has been observed in some cases
- • May require more frequent inspections compared to other models
- • Annual re-arming kit checks are necessary
Typical Vessels:
Passenger shipsCargo vesselsFerriesOffshore supply vessels
Certifications:
SOLASUSCGISO 12402
Decision Guide: Choose if you prioritize compliance with international maritime safety standards and require a reliable, easy-to-use life jacket. Avoid if you have experienced issues with the specific model's known failures or if your vessel has unique requirements not met by this life jacket.
Use Cases: Typically deployed on commercial vessels, passenger ships, and offshore platforms where crew safety is paramount and SOLAS compliance is mandatory.
Survitec Survitec Pilot Ladder PL-12
12m, ISO 799
· Crew Evacuation
length_m: 12
compliance: ISO_799
Common Failures:
- • Manila/synthetic rope aging
- • Step replacement needed
- • Shackle corrosion
Service: Inspect before every use; store dry and covered.
Spares: Survitec: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Survitec Embarkation Ladder 15m
15m, SOLAS III
· Crew Evacuation
length_m: 15
compliance: SOLAS_III
Common Failures:
- • Step tread deterioration
- • Side rope UV damage
- • Storage drum corrosion
Service: Inspect annually; deploy for test during drills.
Spares: Survitec: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Survitec Davit-Launched Liferaft System 25P
25 person
· Crew Evacuation
· davit_launched
type: davit_launched
compliance: SOLAS_III
capacity_persons: 25
Common Failures:
- • Hydrostatic release unit expiry
- • Painter line deterioration
- • Cradle lashing corrosion
Service: Replace HRU before expiry date; inspect painter line annually.
Spares: Survitec: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Survitec Marine Evacuation System MES
Per SOLAS III, 300+ persons
· Crew Evacuation
· MES
type: MES
compliance: SOLAS_III
capacity_persons: 300
Common Failures:
- • Slide deployment mechanism failure
- • Inflation system malfunction
- • Liferaft painter tangle
Service: Annual servicing by approved service station required.
Spares: Survitec: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Survitec Tender-1 MOB Boat
5 persons
· Crew Evacuation
· MOB_boat
type: MOB_boat
length_m: 4.0
capacity_persons: 5
Common Failures:
- • Outboard motor corrosion
- • Lifting hook wear
- • Buoyancy chamber leak
Service: Flush motor after every deployment; test buoyancy chambers quarterly.
Spares: Survitec: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec 1000S Constant Wear
1 person
· Crew Evacuation
· constant_wear
type: constant_wear
solas: True
Common Failures:
- • Zipper wear from daily use
- • Fabric abrasion
- • Seal degradation
Service: Designed for daily wear on offshore helicopters. Replace per wear condition.
Spares: Survitec: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec (Crewfit) Crewfit 275N
1 person
· Crew Evacuation
· inflatable
buoyancy_n: 275
type: inflatable
solas: True
chambers: 2
Common Failures:
- • Auto-inflate bobbin dissolution failure
- • CO2 cylinder corrosion
- • Bladder puncture
Service: Annual service. Replace CO2 + bobbin cartridge annually.
Spares: Survitec (Crewfit): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec (Crewsaver) ErgoFit Immersion Suit
1 person
· Crew Evacuation
· insulated
type: insulated
solas: True
Common Failures:
- • Zipper failure
- • Neoprene aging
- • Reflective tape peeling
- • Buddy line deterioration
Service: Ergonomic design for easier donning. Annual inspection.
Spares: Survitec (Crewsaver): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec (RFD) Seastream SOLAS A 25P
25 persons
· Crew Evacuation
persons: 25
solas_pack: A
brand: RFD
Common Failures:
- • CO2 cylinder leak
- • Canopy fabric deterioration
- • Inflation valve failure
- • Equipment pack water ingress
Service: Service at Survitec approved stations worldwide
Spares: Survitec (RFD): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec (RFD) Seastream SOLAS A 12P
12 persons
· Crew Evacuation
persons: 12
solas_pack: A
brand: RFD
Common Failures:
- • CO2 cylinder corrosion
- • Floor inflation failure
- • Painter wear
Service: Annual service mandatory
Spares: Survitec (RFD): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec (RFD) Seasava SOLAS B 20P
20 persons
· Crew Evacuation
persons: 20
solas_pack: B
brand: RFD
Common Failures:
- • CO2 cylinder corrosion
- • Canopy UV degradation
- • Inflation tube puncture
Service: SOLAS B pack — for short international voyages
Spares: Survitec (RFD): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec (RFD) Seastream SOLAS A 6P
6 persons
· Crew Evacuation
persons: 6
solas_pack: A
brand: RFD
Common Failures:
- • CO2 cylinder corrosion
- • Canopy deterioration
- • Painter wear
Service: Smallest Seastream raft. Annual service.
Spares: Survitec (RFD): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec (RFD) Seastream SOLAS A 16P
16 persons
· Crew Evacuation
persons: 16
solas_pack: A
brand: RFD
Common Failures:
- • Inflation failure
- • Floor tube puncture
- • Equipment pack water damage
Service: Mid-size Seastream. Annual service at Survitec station.
Spares: Survitec (RFD): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec (RFD) Seasava SOLAS B 10P
10 persons
· Crew Evacuation
persons: 10
solas_pack: B
brand: RFD
Common Failures:
- • CO2 cylinder leak
- • Canopy UV damage
- • HRU corrosion
Service: SOLAS B pack for short voyages
Spares: Survitec (RFD): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec (RFD) Seasafe 275N
1 person
· Crew Evacuation
· inflatable
buoyancy_n: 275
type: inflatable
solas: True
Common Failures:
- • Inflation mechanism failure
- • Bladder degradation
- • Light battery expiry
Service: Annual service at Survitec station
Spares: Survitec (RFD): Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd 25-person "Crewsaver" davit-launched SOLAS A or SOLAS B inflatable liferaft in deck-mounted triangular container for float-free operation.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Automatically Self-righting Liferaft - 35 person’s davit-launched canopied inflatable automatically self-righting
Liferaft packages for extended service intervals (RFD Endura R 35 SR DL (also known as DSB LR 97 E 35LSR, SURVITEC ESR35DL,
SURVITEC ZODIAC EPS 35DL, CREWSAVER ESR, ELLIOT ESR).)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Automatically self-righting liferafts: inflatable -35 persons throw-over/roll-over canopied inflatable automatically
self-righting liferaft packages for extended service intervals (RFD Endura R 35 SR TO (also known as SURVITEC ESR, DSB LR97E, SURVITEC
ZODIAC EPS, CREWSAVER ESR, ELLIOT ESR).)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Canopied reversible inflatable liferaft - 109 Persons roll over canopied reversible inflatable liferaft (MARIN-ARK Liferaft)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Canopied reversible liferafts - 158 persons canopied reversible inflatable liferaft (MARIN ARK II Liferaft)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Canopied reversible liferafts - 50-person roll-over canopied reversible inflatable liferaft (RFD SURVIVA 50 (also known as “BEAUFORT SEAFARER 50, SURVITEC ZODIAC
50 & DBC 50”))
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Canopied reversible liferafts (RFD SURVIVA 100)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd "FERRYMAN 25" (also known as "RFD ELLIOT", "RFD CREWSAVER" or "SURVITEC SURVIVAL PRODUCTS"), 25-person capacity inflatable buoyant apparatus, packed in a rigid FRP container.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd "FERRYMAN 30" (also known as "RFD ELLIOT", "RFD CREWSAVER", "SURVITEC", "SURVITEC ZODIAC", "SSPI", or "DBC"), 30-person capacity inflatable buoyant apparatus, packed in a rigid FRP container.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd "FERRYMAN 50" (also known as "SURVITEC", "SURVITEC ZODIAC", "SSPI", "RFD ELLIOT", "RFD CREWSAVER", or "DBC"), 50-person capacity inflatable buoyant apparatus, packed in a rigid FRP container.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Inflatable Liferaft -12 persons, 16 persons, 20 persons, 25 persons davit launched canopied inflatable
liferafts (RFD Surviva DL MKIV” (also known as Beaufort Seafarer DL, DSB LR07L , EV DL
M10, crewsaver, Elliot, Survitec Zodiac SZ2, DBC and Survitec).)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Inflatable Liferaft - 6-person, 8-person, 10-person, 12-person, 16-person, 20-person, 25-person
throw-over/roll-over canopied inflatable liferaft. (“RFD Surviva MKIV” (also known as Beaufort Seafarer, DSB LR07, EV Solas
Silver, EV TO M10, Crewsaver, Elliot, Survitec Zodiac SZ2, DBC and Survitec).)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Inflatable Liferafts - 158 Person Canopied reversible inflatable liferaft packaged for extended
Service intervals. (MARIN-ARK MK II Liferaft)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Inherently Buoyant Adult Lifejacket (1199 Premier Compact)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Inherently Buoyant Lifejacket (Premier 2010 Adult)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Inherently Buoyant Lifejacket (Premier 2010 Child)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Inherently Buoyant Lifejacket (Premier 2010 Infant)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Marin Ark 158-person inflatable liferaft, SOLAS A Pack or B Pack equipment.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Marine Evacuation systems - Vertical chute gravity deployed marine evacuation system with direct access
liferafts (MES II – MARIN ARK MK 1)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Marine evacuation system using single track slide and open reversible liferafts (ESS ORL 302)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Mk4 Extended Service (also known as Survitec RFD, Endura, Survitec Zodiac and Survitec) (Endura R MK4 12-25DL rafts)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Mk4 Extended Service (also known as Survitec RFD, Endura, Survitec Zodiac and Survitec) (Endura R MK4 6-25TO rafts)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Open reversible liferaft - 50-person capacity throw/roll over open reversible liferaft (RFD Ferryman 50, Beaufort 50 ORL, DSB LR14R, Crewsaver, Elliot, Survitec
Zodiac, SSPI, RFD Toyo & Survitec)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Open reversible liferafts - 100 Person capacity throw/roll over open reversible liferaft. (RFD Ferryman 100”, “Beaufort 100 ORL”, “DSB LR14R”, “Crewsaver”, “Elliot”, “
Survitec Zodiac”, “SSPI”, “RFD Toyo” & “Survitec”.)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Open reversible liferafts - 25-person capacity throw/roll over open reversible liferaft. (“RFD Ferryman 25” and “Beaufort 25 ORL”)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Open reversible liferafts - 30-person capacity throw/roll over open reversible liferaft (RFD Ferryman 30 (also known as Beaufort 30, DSB LR14R, Crewsaver, Elliot,
Survitec, Survitec Zodiac, SSPI, RFD Toyo).)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd RFD Surviva DL Mk IV (also known as Survitec RFD, Survitec Zodiac and Survitec) (Surviva Mk4 Family DL rafts (12-25 DL))
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd RFD Surviva TO Mk IV (also known as Survitec RFD, Survitec Zodiac and Survitec) (Surviva Mk4 Family TO rafts (6-25 TO))
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Survitec Zodiac 100-person "TOSR" self-righting SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Survitec Zodiac type "USCG IBA 151" or "USCG HSCR 151", 151-person inflatable buoyant apparatus. May also be branded as Elliot, Crewsaver, or SSPI.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Survitec Zodiac type "USCG IBA 4", 4-person inflatable buoyant apparatus, packed in a rigid FRP container or fabric valise.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Survitec Zodiac type "USCG IBA 6", 6-person inflatable buoyant apparatus packed in a rigid FRP round container, low-profile container, or fabric valise.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "RFD ELLIOT" 25-person SOLAS A or SOLAS B inflatable liferaft, packed in a cylindrical U.S. Navy-style container.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA" 50, 50-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "Surviva Mk3" 10, 10-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 12, 12-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 12 DL, 12-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 16, 16-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 16 DL, 16-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 20, 20-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 20 DL, 20-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 25, 25-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 25 DL, 25-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 4, 4-person "A" or "B" inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 6, 6-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk3" 8, 8-person SOLAS A or SOLAS B inflatable liferaft.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 10, 10-person SOLAS A or SOLAS B inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 12, 12-person SOLAS A or SOLAS B inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 12 DL, 12-person SOLAS A or SOLAS B davit-launched inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 16, 16-person SOLAS A or SOLAS B inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 16 DL, 16-person SOLAS A OR SOLAS B inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 20, 20-person SOLAS A or SOLAS B inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 20 DL, 20-person SOLAS A or SOLAS B davit-launched inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 25, 25-person SOLAS A or SOLAS B inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 25DL, 25-person davit-launched SOLAS A or SOLAS B inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 4, 4-person "A" or "B" inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 6, 6-person SOLAS A or SOLAS B inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type "SURVIVA Mk4" 8, 8-person SOLAS A or SOLAS B inflatable liferaft. (RFD) Elliot, (RFD) Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, DSB LR07, and Survitec Zodiac brands.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type USCG Mk4 4-person Coastal Service inflatable liferaft for domestic service. Elliot, Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, and Survitec Zodiac brands (also known as "RFD ELLIOT" or "RFD CREWSAVER").
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type USCG Mk4 4-person inflatable buoyant apparatus. Elliot, Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, and Survitec Zodiac brands (also known as "RFD ELLIOT" or "RFD CREWSAVER").
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type USCG Mk4 6-person Coastal Service inflatable liferaft for domestic service. Elliot, Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, and Survitec Zodiac brands (also known as "RFD ELLIOT" or "RFD CREWSAVER").
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type USCG Mk4 6-person inflatable buoyant apparatus. Elliot, Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, and Survitec Zodiac brands (also known as "RFD ELLIOT" or "RFD CREWSAVER").
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type USCG Mk4 8-person Coastal Service inflatable liferaft for domestic service. Elliot, Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, and Survitec Zodiac brands. (Also known as "RFD ELLIOT" or "RFD CREWSAVER").
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Type USCG Mk4 8-person inflatable buoyant apparatus. Elliot, Crewsaver, SSPI, New Wave, DBC, RFD Shoresava, and Survitec Zodiac brands (also known as "RFD ELLIOT" or "RFD CREWSAVER").
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Vertical chute gravity deployed marine evacuation system with direct access
rafts. (MARIN-ARK MK2 MES Including additional Primary Capacity Arrangement.)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Survitec Group Ltd Vertical chute gravity deployed marine evacuation system with the direct access liferafts (Marin Ark Mk1)
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: Survitec Group Ltd: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING 25DK+
25 persons
· Crew Evacuation
persons: 25
solas_pack: A
launch: davit
service_interval_months: 12
Common Failures:
- • CO2 inflation cylinder corrosion
- • Canopy fabric UV degradation
- • Hydrostatic release expiry
- • Painter line chafe
Service: Annual service at VIKING station. Hydrostatic release every 2 years. Full overhaul every 3 years.
Spares: VIKING: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING 20DK+
20 persons
· Crew Evacuation
persons: 20
solas_pack: A
launch: davit
Common Failures:
- • CO2 cylinder corrosion
- • Floor inflation failure
- • Canopy deterioration
Service: Annual service mandatory. Replace HRU every 2 years.
Spares: VIKING: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING 16DK+
16 persons
· Crew Evacuation
persons: 16
solas_pack: A
Common Failures:
- • Inflation valve leak
- • Canopy fabric tear
- • Boarding ramp deterioration
Service: Service at approved station annually
Spares: VIKING: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING 12DK+
12 persons
· Crew Evacuation
persons: 12
solas_pack: A
Common Failures:
- • CO2 cylinder corrosion
- • Canopy deterioration
- • Equipment pack expiry
Service: Annual service, 3-year overhaul
Spares: VIKING: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING 10DK+
10 persons
· Crew Evacuation
persons: 10
solas_pack: A
Common Failures:
- • Inflation system failure
- • Painter line chafe
- • HRU expiry
Service: Common on cargo vessels
Spares: VIKING: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING 8DK+
8 persons
· Crew Evacuation
persons: 8
solas_pack: A
Common Failures:
- • CO2 cylinder corrosion
- • Canopy UV damage
- • Floor tube puncture
Service: Annual service at VIKING station
Spares: VIKING: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING 6DK+
6 persons
· Crew Evacuation
persons: 6
solas_pack: A
Common Failures:
- • CO2 inflation failure
- • Canopy deterioration
- • Painter line wear
Service: Smallest VIKING SOLAS raft. Annual service.
Spares: VIKING: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING IBA 6
6 persons
· Crew Evacuation
· inflatable_boarding_aid
persons: 6
type: inflatable_boarding_aid
Common Failures:
- • Inflation failure
- • Fabric wear from repeated use
- • CO2 cylinder depletion
Service: Specialized for pilot/boarding operations. Annual service.
Spares: VIKING: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS C-110 & C-110 MKI D
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS C-140
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS C - 230
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS C-65
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS C-85
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS D-140
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS D-200
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Davit E-90
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS DIB125
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS DIB 32
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS E-110
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS E-60
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS E-65
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS E-80
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS GES-18 MKII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS GES-25 MKII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS GES-40 MKII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS GES-40 MKII ULS
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS GES-45
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS GES-52 MK I
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS H-160, H160 S
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS HD-18 & HD-18 MKII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS HD-21 & HD-21 MKII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS HD-25, HD-25F
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS HD-30B, HD-30F, HD-30S, HD-30 MKII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS HD-40
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS HD-45
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS HD-50
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS HRS-10
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS HRS-20
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS HRS-30
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS JYN-100 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS JYN-115 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS JYN-50 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS JYN-57 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS JYN-65 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS JYN-74 DC/T davit-launched, 7.35 m x 2.68 m x 3.00 m, 52-person, totally enclosed cargo (DC) lifeboat, or tanker (T) fire-protected lifeboat with water spray and air system, constructed of fiberglass reinforced plastic.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS JYN-74 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS JYN-75 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS JYN-80 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS JYN-85 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS K4-D, K4-D FM
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS K7-D FM
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS LH-100
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS LH-140 MKIII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS LH-185
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS LH-200 S
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS LHD-110
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS LHD-150
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS LHD-200
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS LHD-90
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Magnum-700 Twin Waterjet
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Magnum 750 NC/LC
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Mako-655 MKI FRC Outboard
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS MAKO-655 MKI Sterndrive
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS MAKO-655-NO MKI Waterjet
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Mako-655 Waterjet MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Mako 655 Waterjet MKI, 6.55 m X 2.70 m X 2.26 m, 12 or 15-person FRP rigid fast rescue boat.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Marathon-800 Sterndrive
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Mathilda-74 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Matrix-450 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Maud-94 MkI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Maxima-120
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Maya-850 MKI Waterjet
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Merlin-615 MKI Outboard
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Merlin-615 MKI Waterjet
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Merlin 615 R MKI Outboard
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Merlin-615 R MKI Outboard
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Merlin-615 R MKI Waterjet
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Midget-500 MKII
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Midget-530 MKI / Midget-530 MKII with waterjet/propeller
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Minima-88 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Miriam-85 MKI
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model DIB 32 Drop-in-ball on-load/off-load release mechanism, for use with dual or single point suspension lifeboats and rescue boats; maximum approved working load of 3,200 kg per ball housing.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model DW25 rescue boat winch with a hydraulic motor; maximum safe working load 25 kN (2,550 kg).
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model DW 34 manual winch for single fall liferaft launching appliances with a maximum approved working load of 34 kN.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model E-110 Version 1 or Version 2 twin-fall lifeboat/rescue boat launching davit with a maximum safe working load of 110 kN.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model E-90 twin-fall lifeboat/rescue boat launching davit with a maximum safe working load of 90 kN.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model GES 30 MkII, 9.00 m x 2.75 m x 3.42 m, 40-person, totally enclosed, cargo or tanker (fire-protected) freefall lifeboat of fiberglass reinforced plastic construction.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model HD-30B free-fall lifeboat launching davit with a maximum safe working load of 9300 kg.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model IYJ34-78-82-20-ZPN winch with a hydraulic motor, for HD-30B freefall lifeboat davit; maximum approved working load of 9300 kg.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model JYN 115 DC/T, 11.5 m x 3.8 m x 1.42 m, 136-person, totally enclosed, cargo (DC) lifeboat, or tanker (T) fire-protected lifeboat with water spray and air system, constructed of fiberglass reinforced plastic.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model JYN-57 MkI, 5.70 m x 2.20 m x 1.2 m, 26-person, totally enclosed dry cargo or tanker lifeboat/rescue boat of fiberglass reinforced plastic construction.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model JYN65, 6.5 m x 2.3 m x 3.1 m, 36 person, totally enclosed, SOLAS rigid rescue boat with fiberglass reinforced plastic construction.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model JYN65DC (cargo version), 6.5 m x 2.3 m x 3.1 m, 36-person, totally enclosed lifeboat of fiberglass reinforced plastic construction.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model JYN65T (tanker version), 6.5 m x 2.3 m x 3.1 m, 36 person, SOLAS, totally enclosed, fire-protected lifeboat, with a self-contained air support system and fiberglass reinforced plastic construction.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model JYN85 DC/T, 8.5 m x 3.15 m x 3.3 m, 80 person totally enclosed FRP cargo (DC) or fire protected (T) lifeboat/rescue boat with a self-contained air support system, available with one or two side doors.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model JYN85 DC/T, 8.5 m x 3.15 m x 3.3 m, 80 person totally enclosed FRP cargo (DC) or fire-protected (T) lifeboat/rescue boat with a self-contained air support system; available with one or two side doors.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model LH-100 twin-fall lifeboat launching davit with a maximum safe working load of 10,000 kg.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model LHD-60 MKII lifeboat davit with a maximum safe working load of 6000 kg.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model Merlin-615 6.25 m x 2.45 m x 2.5 m, 14-person FRP rigid fast rescue boat.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model Midget-500 MKII, 5.1 m (16.7 ft) x 2.07 m (6.79 ft) x 1.90 m (6.23 ft), 6-person FRP rigid rescue boat.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model Midget 530 MkII 5.32 m x 2.07 m x .76 m, 8-person rigid FRP rescue boat.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model NDA-25 HST single-fall rescue boat davit with a maximum safe working load of 2800 kg.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model NRB-30 Mk II rescue boat davit with a maximum safe working load of 3000 kg.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model NRC-25 MKII rescue boat launching davit with a working radius of 4.5 m, 4 m, or 3.5 m; each with maximum safe working load of 25 kN (2,550 kg).
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model NRC-R-34 single-fall liferaft launching appliance with a maximum approved working load of 34 kN.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model NW-85 lifeboat winch (type DP-LB, SP-LB, SP-RB, or DP-RB) with electric motor and a maximum approved working load of 85 kN.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model NWR-30S rescue boat winch with hydraulic motor; maximum approved working load of 3000 kg.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Models NW-120 and NW-150 lifeboat/rescue boat winch with electric motor; maximum approved working load of 120 kN (60 kN on each drum) and 150 kN (75 kN of each drum), respectively.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Models NW-45, NW-45L, and NW-45 V2 lifeboat/rescue boat winches with electric motor and maximum safe working loads as follows:
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model TOR Mk2-S 12T on-load/offload release mechanism, for use with single and double-point suspension lifeboats and rescue boats with a maximum approved working load of 12.0 tonnes per hook.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model TOR Mk2-S 3.36 T on-load/offload release mechanism, for use with single and double-point suspension lifeboats and rescue boats with a maximum approved working load of 3.36 tonnes per hook.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model TOR Mk2-S 6T on-load/offload release mechanism, for use with single and double-point suspension lifeboats and rescue boats with a maximum approved working load of 6.0 tonnes per hook.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model TOR Mk2-S 9T on-load/offload release mechanism, for use with single and double-point suspension lifeboats and rescue boats with a maximum approved working load of 9.0 tonnes per hook.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model VNJY-55, 5.50 m x 2.80 m x 2.68 m, 40-person, totally enclosed dry cargo or tanker lifeboat/rescue boat of fiberglass reinforced plastic construction.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Model VNW-50 lifeboat/rescue boat winch with an electric motor; maximum approved working load of 50 kN (1000 kg).
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Munin 980
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDA-16
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDA-25
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDA-25 HST
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDA-40 & NDA-40 HST
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDA-40 / NDA-40 HST / NDA-40 HS
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDA-65 & NDA-65 NO
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDC-65
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDC-L-9,4
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDSC-25
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDSC-34
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NDSC-R-23
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NFFH-50
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Norsafe K4-D and K4-D FM off-load release hook, for use only with single-point suspension rescue boats; maximum approved safe working load is 4000 kg.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Norsafe Marine T15BML, T25BML, T25FWL, T40FWL, T40FWS, T60FEL-T, T75FEL-T & T90FEL-T
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Norsafe Marine T15BML, T25BML, T25FWL, T40FWL, T40FWS, T60FEL-T, T75FEL-T & T90FEL-T; CN15B0302, CN15B0304, CN15B0311
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NRB-20, NRB-20 MKII & MKIII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NRB-30 MKII/MKIII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NRB-40 MKIII & NRB-40 MKIV
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NRC-25 MKI & MKII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NRC-34
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NW-120
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NW-120-NO
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NW-150
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NW-230
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NW-45 & NW-45 V2
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NW-85
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NWR-30 S
Persons capacity per SOLAS certification
· Crew Evacuation
source: uk-mca
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS NWR-40 S MKII & NWR-40 S MKIII
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS RCH36
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS SW-45
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS TOR MK2-S 3,36t
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Tor MK2-S 6t
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Tor MK2-S 9T
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Tor on Load MK2 14 T
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Tor on load MK2-S 12t
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Type C-110 cantilevered, twin-fall platform Davit with a maximum safe working load of 120 kN.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Type C-140 cantilever, fixed arm, twin-fall lifeboat launching davit with a maximum safe working load of 150 kN.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Type E-65 lifeboat/rescue boat davit; maximum safe working load 65 kN (6625 kg) (32.5 kN (3312 kg) per arm).
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Type LH-185 twin-fall lifeboat launching davit with a maximum safe working load of 200 kN.
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Type NDC-40 rescue boat launching davit with a maximum safe working load of 39.2 kN (4000 kg).
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS Type NW-200 lifeboat winch with a maximum safe working load of 200 kN (20395 kg).
Persons capacity per SOLAS certification
· Crew Evacuation
source: uscg-cgmix
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS VNJY-55
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS VNJY-68
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS VNLD-15
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS VNRD-15
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
VIKING Life-Saving Equipment Norway AS VNW-50
Persons capacity per SOLAS certification
· Crew Evacuation
source: dnv-approval-finder
Common Failures:
- • Hydrostatische Auslöseeinheit (HRU) abgelaufen — KRITISCHER Sicherheitsfehler
- • CO2-Flasche Druckverlust durch Korrosion/Alterung
- • Stoff-Alterung durch UV-Exposition an Deck
- • Fangleine Korrosion/Blockierung
- • Überlebensausrüstung abgelaufen (Leuchtraketen, Wasser, Proviant)
Service: Jährliche Wartung bei zugelassener Service-Station PFLICHT (SOLAS/MSC.1/Circ.1328). HRU-Austausch per Herstellerintervall (typisch 2 Jahre). Rettungsinsel-Austausch/Rezertifizierung alle 5 Jahre.
Spares: VIKING Life-Saving Equipment Norway AS: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
YSmarines YS SOLAS A 20P
20 persons
· Crew Evacuation
persons: 20
solas_pack: A
origin: Asia
Common Failures:
- • CO2 cylinder corrosion
- • Fabric bonding failure
- • HRU expiry
Service: Asian manufacturer, CCS approved
Spares: YSmarines: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
YSmarines YS SOLAS A 10P
10 persons
· Crew Evacuation
persons: 10
solas_pack: A
origin: Asia
Common Failures:
- • CO2 cylinder corrosion
- • Fabric degradation
- • HRU failure
Service: Asian manufacturer
Spares: YSmarines: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
YSmarines YS SOLAS A 25P
25 persons
· Crew Evacuation
persons: 25
solas_pack: A
launch: davit
origin: Asia
Common Failures:
- • CO2 inflation system failure
- • Canopy deterioration
- • Davit connection issue
Service: Davit-launched large capacity. CCS approved.
Spares: YSmarines: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Zodiac Open Sea SOLAS A 20P
20 persons
· Crew Evacuation
persons: 20
solas_pack: A
origin: France
Common Failures:
- • CO2 inflation failure
- • Canopy UV damage
- • HRU failure
Service: French manufacturer, global service network
Spares: Zodiac: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Zodiac Open Sea SOLAS A 10P
10 persons
· Crew Evacuation
persons: 10
solas_pack: A
origin: France
Common Failures:
- • CO2 inflation failure
- • Canopy deterioration
- • Painter line wear
Service: French manufacturer, global service.
Spares: Zodiac: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.
Zodiac Open Sea SOLAS A 25P
25 persons
· Crew Evacuation
persons: 25
solas_pack: A
launch: davit
origin: France
Common Failures:
- • CO2 cylinder leak
- • Davit hook engagement failure
- • Canopy tear
Service: Davit-launched version. Annual service.
Spares: Zodiac: Wartung NUR bei zugelassener Service-Station. HRU an Bord vorhalten. Jährlicher Service Pflicht.