Flame Detector
medium
UV/IR flame detectors for engine rooms and cargo areas
Known Models (3)
Autronica AutroSafe Flame Detector BFL-400
per point
· Fire Suppression / Detection
· triple_ir_uv_flame
type: triple_ir_uv_flame
solas: True
atex: True
Common Failures:
- • Sensor window fouling
- • UV sensor aging
- • ATEX certification issue
Service: Triple-spectrum (UV/IR/IR). ATEX certified.
Spares: Autronica: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
Consilium Salwico UV/IR Flame Detector
per point
· Fire Suppression / Detection
· uv_ir_flame
type: uv_ir_flame
solas: True
Common Failures:
- • UV sensor degradation from age
- • IR window contamination
- • False alarm from welding/sunlight
Service: For engine rooms, pump rooms. Annual sensitivity test.
Spares: Consilium: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
Det-Tronics X3302 MultiSpectrum Flame
per point
· Fire Suppression / Detection
· multispectrum_flame
type: multispectrum_flame
solas: True
Common Failures:
- • Window contamination
- • Heater element failure
- • Electronics aging
Service: Offshore and marine applications. Triple IR + UV.
Spares: Det-Tronics: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.