OS
← Oil Discharge Monitoring Equipment

ODME System

medium
Oil content monitoring and control systems for overboard discharge

Known Models (4)

Deckma OMD-24 ODME
Deckma OMD-24 ODME
0-15 ppm · Ballast Water Oil Content · odme
type: odme
range_ppm: 0-15
marpol: True
origin: Germany
Common Failures:
  • • Sensor contamination
  • • Pump diaphragm failure
  • • Recording unit malfunction
Service: German manufacturer. Annual calibration and survey.
Spares: Ersatzteile über Deckma oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Rivertrace Smart ODME
Rivertrace Smart ODME
0-15 ppm monitoring · Ballast Water Oil Content · odme
type: odme
range_ppm: 0-15
marpol: True
Common Failures:
  • • Optical sensor fouling
  • • Sample pump failure
  • • Flow meter malfunction
  • • Data recording failure
Service: MARPOL mandatory. Annual calibration. Sensor cleaning weekly.
Spares: Ersatzteile über Rivertrace oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
VAF Instruments VAF Marine OCM
VAF Instruments VAF Marine OCM
0-15 ppm · Ballast Water Oil Content · odme
type: odme
range_ppm: 0-15
marpol: True
origin: Netherlands
Common Failures:
  • • Sensor window fouling
  • • Flow control malfunction
  • • Recording failure
Service: Dutch manufacturer. Annual calibration and class survey.
Spares: Ersatzteile über VAF Instruments oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.
Yokogawa (Marex) Yokogawa OCM-15 ODME
Yokogawa (Marex) Yokogawa OCM-15 ODME
0-15 ppm · Ballast Water Oil Content · odme
type: odme
range_ppm: 0-15
marpol: True
Common Failures:
  • • IR sensor drift
  • • Sample line blockage
  • • Data logger failure
Service: Japanese/Norwegian product. Annual calibration.
Spares: Ersatzteile über Yokogawa (Marex) oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.